From July 15, 2023, will low-efficiency energy-using equipment be phased out in Vietnam?
From July 15, 2023, will low-efficiency energy-using equipment be phased out in Vietnam? - Question from Ms. Van (Yen Bai).
From July 15, 2023, will low-efficiency energy-using equipment be phased out in Vietnam?
On May 24, 2023, the Prime Minister issued Decision 14/2023/QD-TTg promulgating the list and roadmap of energy-using vehicles and equipment that must be eliminated and low-efficiency generating sets are not newly built.
Decision 14/2023/QD-TTg will be applied to state agencies, enterprises, organizations and individuals engaged in the import, production and trading of goods specified in Article 3 of this Decision 14/2023/QD-TTg.
However, it will not be applied to vehicles and equipment temporarily imported for re-export, repair, replacement, and energy efficiency testing.
Decision 14/2023/QD-TTg takes effect from July 15, 2023 and Decision 24/2018/QD-TTg will be anulled from July 15, 2023.
What are means and low-efficiency energy-using equipment that must be eliminated in Vietnam?
Pursuant to Article 3 of Decision 14/2023/QD-TTg stipulating list and roadmap of means and low-efficiency energy-using equipment that must be eliminated as follows:
- Group of household appliances:
+ Compact fluorescent lamps, electronic ballasts for fluorescent lamps, electromagnetic ballasts for fluorescent lamps, tube fluorescent lamps;
+ Storage water heater, infrared cooker, induction cooker, LED light, ductless air conditioner, household washing machine, television set, rice cooker, electric fan, refrigerator and freezer.
- Group of office and commercial equipment:
Computer monitors, copiers, printers, laptops, desktops and commercial refrigerators.
- Group of industrial equipment: Three-phase asynchronous electric motors with squirrel cage rotors, distribution transformers, LED lights for street and street lighting, boilers in industrial enterprises.
The above groups of means and equipment, that are not allowed to be imported, produced and sold domestically, are those with energy efficiency failed to meet the minimum energy efficiency level specified in the Vietnamese Standards.
No. |
Name (device) |
National standards |
Roadmap |
I. Household appliance group: |
|||
1 |
Compact fluorescent lamp |
TCVN 7896:2015 |
From the effective date of this Decision |
2 |
Electronic ballasts for fluorescent lamps |
TCVN 7897:2013 |
|
3 |
Electromagnetic ballasts for fluorescent lamps |
TCVN 8248:2013 |
|
4 |
Tube fluorescent lamp |
TCVN 8249:2013 |
|
5 |
Electric fan |
TCVN 7826:2015 |
|
6 |
Household washing machine |
TCVN 8526:2013 |
|
7 |
Electric cooker |
TCVN 8252:2015 |
|
8 |
Led light |
TCVN 11844:2017 |
From April 1, 2025 |
9 |
Kitchen infrared |
TCVN 13373: 2021 |
|
10 |
Induction cooker |
TCVN 13372: 2021 |
|
11 |
Refridgerator |
TCVN 7828:2016 |
|
12 |
Refrigerator and freezer |
TCVN 7828:2013 |
From the effective date of this Decision to the end of March 31, 2025 |
TCVN 7828:2016 |
From April 1, 2025 |
||
13 |
Hot water heater with storage |
TCVN 7898:2009 |
From the effective date of this Decision to the end of March 31, 2025 |
TCVN 7898:2018 |
From April 1, 2025 |
||
14 |
Ductless air conditioner |
TCVN 7830:2015 |
From the effective date of this Decision to the end of March 31, 2025 |
TCVN 7830: 2021 |
From April 1, 2025 |
||
15 |
TVS |
TCVN 9536:2012 |
From the effective date of this Decision to the end of March 31, 2025 |
TCVN 9536: 2021 |
From April 1, 2025 |
||
II. Group of office and commercial equipment: |
|||
1 |
Photocopiers |
TCVN 9510:2012 |
From the effective date of this Decision |
2 |
Printer |
TCVN 9509:2012 |
|
3 |
Computer screen |
TCVN 9508:2012 |
|
4 |
Commercial Refrigerator |
TCVN 10289:2014 |
|
5 |
Laptop |
TCVN 11848: 2021 |
From April 1, 2025 |
6 |
Desktop |
TCVN 13371: 2021 |
|
III. Industrial equipment group: |
|||
1 |
Three-phase asynchronous electric motor with squirrel cage rotor |
TCVN 7540-1:2013 |
From the effective date of this Decision |
2 |
Distribution Transformer |
TCVN 8525:2015 |
|
3 |
LED electric lights for street and street lighting |
TCVN 12666:2019 |
From April 1, 2025 |
4 |
Boilers in industrial plants |
TCVN 8630:2010 |
From the effective date of this Decision to the end of March 31, 2025 |
TCVN 8630:2019 |
From April 1, 2025 |
What types of coal and gas generating sets in low-efficiency thermal power plants in Vietnam are not allowed to be newly built?
Pursuant to Article 3 of Decision 14/2023/QD-TTg stipulating list and roadmap of means and low-efficiency energy-using equipment that must be eliminated as follows:
- Fail to approve investment policy in coal and gas-fired thermal power plants with energy efficiency lower than the prescribed efficiency corresponding to the capacity range of the generating set as prescribed.
- Not allowed to operate coal and gas generating sets whose efficiency at the time of commercial operation is lower than the specified efficiency corresponding to each capacity range of the set as prescribed.
No. |
Engine unit |
Efficiency (%) |
Roadmap |
I. Coal-fired generating sets, crude efficiency according to low calorific value at the unit's rated capacity, in terms of inlet cooling water temperature of 28°C and ambient temperature of 30°C, must be not less than the following value: |
|||
1 |
Units with capacity 50 MW and < 150 MW |
34.0 |
From the effective date of this Decision |
2 |
Units with capacity 150 MW and < 300 MW |
38.0 |
|
3 |
Units with capacity 300 MW and < 600 MW |
39.0 |
|
4 |
Units with capacity 600 MW and < 800 MW |
41.0 |
|
5 |
The unit has a capacity of ≥ 800 MW |
43.0 |
|
II. The gas-fired generating sets, using single-cycle gas turbine technology, the efficiency of the gas turbines (ambient air state: 15°C, 760 mmHg and 60% humidity) is not lower than: |
|||
1 |
Units with capacity 100 MW and < 150 MW |
33.0 |
From the effective date of this Decision |
2 |
Units with capacity ≥ 150 MW and < 200 MW |
34.0 |
|
3 |
Units with capacity ≥ 200 MW and < 300 MW |
37.0 |
|
4 |
Unit with capacity ≥ 300 MW |
39.0 |
|
III. Gas-fired generating units, using combined cycle gas turbine technology, the efficiency of the combined cycle gas turbine assembly (ambient air state: 15°C, 760 mmHg and humidity humidity 60%) according to the unit capacity of a single gas turbine unit, not less than: |
|||
1 |
Units with capacity 100 MW and < 150 MW |
49.5 |
From the effective date of this Decision |
2 |
Units with capacity ≥ 150 MW and < 200 MW |
51.0 |
|
3 |
Units with capacity ≥ 200 MW and < 300 MW |
55.5 |
|
4 |
Unit with capacity ≥ 300 MW |
58.5 |
What are responsibilities of the Ministry of Science and Technology in managing and supporting the removal of energy-using vehicles and equipment that must be removed, and low-efficiency generating sets that are not newly built in Vietnam?
Pursuant to Article 4 of Decision 14/2023/QD-TTg stipulating responsibilities of the Ministry of Science and Technology as follows:
Implementation organization
1. The Ministry of Science and Technology is responsible for
a) Assume the prime responsibility for, and coordinate with ministries, ministerial-level agencies, government-attached agencies and People's Committees of provinces and central-affiliated cities in, implementing solutions to support the removal of vehicles, energy-using equipment must be eliminated, low-efficiency generating sets must not be newly built as prescribed in this Decision.
b) Assume the prime responsibility for, and coordinate with concerned ministries and branches in, formulating national standards on energy efficiency and minimum energy efficiency levels of energy-intensive vehicles and equipment.
c) Based on the socio-economic development situation and state management requirements in the course of implementation, assume the prime responsibility for, and coordinate with line ministries and sectors in, reviewing and submitting to the Prime Minister for decision. intend to amend, supplement or replace the list of energy-using vehicles and equipment that must be eliminated and generating sets that are not newly built.
2. The Ministry of Industry and Trade is responsible for
a) Assume the prime responsibility for, and coordinate with the Ministry of Science and Technology in, inspecting and inspecting the compliance with regulations on the elimination of low-efficiency energy-using equipment and low-efficiency generating sets that are not new construction specified in this Decision.
...
Thus, when managing and supporting the elimination of energy-using vehicles and equipment that must be removed, and low-efficiency generating sets that are not newly built, the Ministry of Science and Technology is responsible for as follows:
- Assume the prime responsibility for, and coordinate with ministries, ministerial-level agencies, government-attached agencies and People's Committees of provinces and central-affiliated cities in, deploying solutions to support the removal of vehicles and energy-using equipment must be eliminated, low-efficiency generating sets are not newly built.
- Assume the prime responsibility for, and coordinate with concerned ministries and branches in, formulating national standards on energy efficiency and minimum energy efficiency levels of energy-intensive vehicles and equipment.
- Based on the socio-economic development situation and state management requirements in the course of implementation, assume the prime responsibility for, and coordinate with line ministries and sectors in, reviewing and submitting to the Prime Minister for amending, supplementing or replacing the list of energy-using vehicles and equipment that must be removed and generating sets that are not newly built.
Best regards!