Here is the noteworthy content stipulated in Circular 11/2018/TT-BXD of Ministry of Construction of Vietnam promulgating the National Technical Regulation on underground railway structures - QCVN 08:2018/BXD.
The structures of urban underground railway structures in Vietnam must meet the following fire resistance limits:
Structure Name | Fire Resistance Limit, not less than |
Shell of station halls, intermediate halls, tunnels, and structures adjacent to tunnels or stations | R90 |
Shell of train tunnels and dead-end tunnels | R90 |
Station pillars | R90 |
Partition walls of elevator shafts and stairwells in tunnels | REI 120 |
Walls of stairwells | REI 120 |
Walls of auxiliary stations | R 90/EI 60 |
Walls and ceilings of flammable oil and paint storage rooms | REI 120 |
Shell of elevator shafts and station lobbies | R60 |
Partition walls between passageways and cable-ventilation trenches | R 45 |
Beams, stair body, stairwells | R60 |
Covering structure of the beam slab's inner layer | REI 60/R60 |
Walls of escape routes between tunnels | R 45 (EI 45) |
Self-closing fire doors | EI30 |
Load-bearing and enclosing structures above platforms and station passageways | REI 90 |
Suspended ceilings in corridors | RE 15 |
Refer to the relevant regulations in Circular 11/2018/TT-BXD,which comes into force in Vietnam from March 15, 2019.