On November 07, 2017, the Ministry of Natural Resources and Environment of Vietnam issued Circular No. 47/2017/TT-BTNMT, which specifies requirements for equipment for measuring, connecting and transferring data of the establishment having works.
According to Circular No. 47/2017/TT-BTNMT of the Ministry of Natural Resources and Environment of Vietnam, the measuring equipment used in water extraction works must satisfy the following main requirements:
- The value to be measured must be within the measurement range.
- The measuring equipment must operate continuously and transfer information and data to the equipment for storing database of the supervision system;
- Regarding the water level meter, the absolute error must not exceed 01 cm; regarding the flow meter, the relative error must not exceed 5% of the actually measured value.
- Regarding the equipment for automatically measuring water level, discharge, measurement range must not exceed 15 minutes at a time; regarding surveillance cameras, the shutter speed must be at least 01 frame per minute.
- The measuring equipment must undergo calibration and inspection as prescribed.
Circular No. 47/2017/TT-BTNMT of the Ministry of Natural Resources and Environment of Vietnam came into force from December 22, 2017.
-Thao Uyen-