The content is detailed in Circular 21/2016/TT-BYT of Vietnam, which stipulates National Technical Regulation - High Frequency Electromagnetic - Permissible Exposure Level of High Frequency Electromagnetic Intensity in the Workplace
Circular 21/2016/TT-BYT stipulates the permissible levels of induced currents and contact currents through the body from high-frequency electromagnetic fields not exceeding the values specified in the table below:
Frequency | Induced current (mA) | Contact current (mA) | |
Through both legs | Through each leg | ||
3KHz - 100KHz >100KHz - 100MHz >100MHz - 300MHz |
2000 f^(3)^ 200 - |
1000 f^(3)^ 100 - |
1000 f^(3)^ - 100 ^(2)^ |
Notes:
(2) Although various standards provide for the maximum contact currents of high-frequency electromagnetic fields at frequencies above 300MHz, it is currently not possible to perform measurements above this frequency.
(3) f is the frequency measured in MHz.
Note: The measurement of induced currents through the human body is averaged over any 6-minute period, and contact currents are averaged over any 1-second period.
More details can be found in Circular 21/2016/TT-BYT, which comes into force in Vietnam from December 1, 2016.