Multi-path error limits of GSM 900 at RX noise level with a deviation of 400 kHz in Vietnam

In 2016, the Ministry of Information and Communications issued Circular 30/2016/TT-BTTTT stipulating the National Technical Regulations on GSM mobile communication base station equipment.

Circular 30/2016/TT-BTTTT stipulates the multi-path error limits of GSM 900 at RX interference deviation of 400 kHz in Vietnam as follows:

Channel Type Error Measurement Parameter Error Rate for Specific Propagation Conditions
TU50 (non-SFH) TI5 (non-SFH)
FACCH/F (FER) 17.1% 17.1%
TCH/FS (FER) 10.2α% 10.2α%
- class Ib (RBER) 0.72/α% 0.72/α%
- class II (RBER) 8.8% 8.8%

Also according to Circular 30/2016/TT-BTTTT, the multi-path error limits of DCS 1 800 at RX interference deviation of 400 kHz include:

Channel Type Error Measurement Parameter Error Rate for Specific Propagation Conditions
TU50 (non-SFH) TI5 (non-SFH)
FACCH/F (FER) 6.1% 17.1%
TCH/FS (FER) 5.1α% 10.2α%
- class Ib (RBER) 0.45/α% 0.72/α%
- class II (RBER) 8.9% 8.8%

More details can be found in Circular 30/2016/TT-BTTTT, effective from May 1, 2017.