Recently, the Ministry of Industry and Trade (Hanoi, Vietnam) issued the List of Products subject to energy yield testing and Energy Labeling.

Danh muc mat hang kiem tra hieu suat nang luong va dan nhan nang luong moi nhat

Latest List of Products subject to energy yield testing and Energy Labeling in Vietnam (Internet image)

On July 01, 2024, the Minister of Industry and Trade (Hanoi, Vietnam) issued Decision 1725/QD-BCT on the List of Items for Energy Performance Testing and Energy Labeling under the management responsibility of the Ministry of Industry and Trade (Hanoi, Vietnam).

Latest List of Products subject to energy yield testing and Energy Labeling in Vietnam

The list of items for energy performance testing and energy labeling under the management responsibility of the Ministry of Industry and Trade (Hanoi, Vietnam) includes:

HS code

Name of goods according to Circular 31/2022/TT-BTC

Description of products and goods

Standards and technical regulations

Note

Products subject to energy yield testing according to Decision 14/2023/QD-TTg dated May 24, 2023 and Decision 04/2017/QD-TTg dated March 9, 2017 of the Prime Minister of Vietnam

8539.31

- - Fluorescent lamps, hot cathode

Fluorescent light bulbs

 

 

 

8539.31.10

- - - Fluorescent tubes for compact fluorescent lamps

Compact Fluorescent Lamp (CFL)

TCVN 7896:2015

Only applies to power types from 5 W to 60 W

8539.31.20

- - - Other types, straight tubes for other fluorescent lamps

Straight tube fluorescent lamp (FL)

TCVN 8249:2013

Only applies to power types from 4 W to 65 W

8539.31.30

- - - Compact fluorescent light bulbs have built-in ballasts

Compact Fluorescent Lamp (CFL)

TCVN 7896:2015

Only applies to power types from 5 W to 60 W

8504.10.00

- Ballasts used for projector lamps or launch tubes

Electromagnetic ballasts for fluorescent lamps

TCVN 8248:2013

Only applies to power from 4 W to 65 W

8504.10.00

- Ballasts used for projector lamps or launch tubes

Electronic ballast for fluorescent lamps

TCVN 7897:2013

8418.10

- Combination freezer (1) (equipment with separate ice and refrigeration chambers), with separate opening doors or separate outer drawers, or a combination thereof:

Refrigerators, Freezers Commercial refrigerators

TCVN 7828:2016

TCVN 10289:2014

Only applicable to 1000L type. Natural convection or forced air cooling. Do not apply absorption cooling, commercial cabinets, or specialized refrigeration equipment

 

- - Only separate opening doors:

8418.10.31

- - - Household type, with capacity not exceeding 230 liters

8418.10.32

- - - Other household appliances, with a capacity of over 230 liters

8418.10.39

- - - Others

8418.10.91

- - - Counters, display cabinets and the like, fitted with refrigeration equipment, with a capacity of over 200 liters

8418.10.99

- - - Others

 

- Refrigerator (1), household type:

8418.21

- - Compressor usage type:

8418.21.10

- - - Capacity not exceeding 230 liters

8418.21.90

- - - Others

8418.29.00

- - Others

8418.30

- Freezer (1), top door type, capacity not exceeding 800 liters:

8418.30.10

- - Capacity not exceeding 200 liters

8418.30.90

- - Others

8418.40

- Freezer (1), front door type, capacity not exceeding 900 liters:

8418.40.10

- - Capacity not exceeding 200 liters

8418.40.90

- - Others

8418.50

- Types of other interior designs (cabinets, drawers, counters, display cases and the like) for storage and display, fitted with refrigeration or freezing equipment:

 

- - Counters, display cabinets and the like, fitted with refrigeration equipment, with a capacity of over 200 liters:

8418.50.19

- - - Others

8418.50.99

- - - Others

8516.60.10

- - Rice cooker

Electric cooker

TCVN 8252:2015

Only applies to types up to 1000W

8414.51

- - Table fans, floor fans, wall fans, window fans, ceiling fans or roof fans, with a built-in electric motor of an output not exceeding 125 W

Electric fan

TCVN 7826:2015

 

8414.51.10

- - - Table fans and box fans

 

- - - Others:

8414.51.91

- - - - There is a protective net

8414.51.99

- - - - Others

8528.72.92

- - Liquid crystal display (LCD), light-emitting diode (LED) and other flat panel displays

TVS

TCVN 9536:2012

 

8528.72.99

- - Others

8516.10

- Electric equipment for instant hot water heating or storage hot water heating and immersion hot water heating

The water heater has storage

TCVN 7898:2009

TCVN 7898:2018

- Electric water heater with storage for household and similar purposes with a capacity of up to 40 liters ( TCVN 7898:2009 )

- Electric water heater with storage for household and similar purposes with a capacity of up to 40 liters ( TCVN 7898:2018 )

□ This standard does not apply to drinking water heaters.

 

- - Instantaneous water heater or storage water heater:

8516.10.19

- - - Others

8415.10.20

- - Cooling capacity not exceeding 21.10 kW

Air conditioner

TCVN 7830:2015

TCVN 7830:2021

This standard specifies the energy efficiency level and the method for determining the energy efficiency for ductless air conditioners using a sealed motor-compressor and an air-cooled condenser, single assembly or two clusters, with or without inverter with nominal cooling capacity up to 12 000 W (41 000 BTU/h).

- This standard does not apply to water-cooled air conditioners, ducted types, portable types, floor-standing types, ceiling-mounted types, air conditioners with more than two clusters or air conditioners with The air conditioner uses three-phase electricity.

8450.11

- - Fully automatic machine:

Household washing machine

TCVN 8526:2013

Only applicable to types with a capacity of 2kg to 15kg of dry fabric per wash

8450.11.10

- - - Type with a capacity of not more than 6 kg of dry fabric per wash

8450.11.90

- - - Others

8450.12

- - Other washing machines, with centrifugal drying function:

8450.12.10

- - - Type with a capacity of not more than 6 kg of dry fabric per wash

8450.12.90

- - - Others

8450.19

- - Others:

 

- - - Electrically operated:

8450.19.11

- - - - Type with a capacity of not more than 6 kg of dry fabric per wash

8450.19.19

- - - - Others

 

- - - Others:

8450.19.91

- - - - Type with a capacity of not more than 6 kg of dry fabric per wash

8450.19.99

- - - - Others

8450.20.00

- Washing machine, capable of holding over 10 kg of coarse fabrics per wash

8539.52

- - Light-emitting diode (LED) lamps:

Led light

TCVN 11844:2017

TCVN 12666:2019

Only applicable to lamps with built-in ballasts E27 and B22, tube bulbs G5 and G13 with capacity up to 60W, voltage not exceeding 250V

LED street and street lighting, capacity greater than or equal to 20W, including those with separate controllers.

8539.52.10

- - - Screwed lamp head type

8539.52.90

- - - Others

8443.39.10

- Electrostatic copiers, which work by reproducing the original image directly onto the copy (direct reproduction process)

Photocopiers

TCVN 9510:2012

 

8443.39.30

- Other photocopiers incorporating optical systems

8443.31

- - Machines combining two or more functions of printing, copying or faxing, capable of connecting to an automatic data processing machine or a network connection:

Printer

TCVN 9509:2012

 

 

- - - Printer-copier, printing using inkjet technology:

8443.31.11

- - - - Color type

8443.31.19

- - - - Others

 

- - - Printer-copy machines, printing with laser technology:

8443.31.21

- - - - Color type

8443.31.29

- - - - Others

 

- - - Combined printer-copy-fax:

8443.31.31

- - - - Color type

8443.31.39

- - - - Others

 

- - - Others:

8443.31.91

- - - - Combined printer-copy-scan-fax

8443.31.99

- - - - Others

8528.72.92

- Liquid crystal display (LCD), light-emitting diode (LED) and other flat panel displays

Computer screen

TCVN 9508:2012

Applicable to types up to 24 inches

Exclude screens used in medicine and specialized in industry

8471.30.20

- - Laptop computers including notebooks and subnotebooks

Laptop

TCVN 11848:2017

TCVN 11848:2021

 

8471.41.10

- - - Personal computers other than portable computers of subheading 8471.30

Desktop

TCVN 13371:2021

 

8471.41.90

- - - Others

8471.49.10

- - - Personal computers other than portable computers of subheading 8471.30

8471.49.90

- - - Others

8501.52

- - Capacity above 750W is less than 75kW

Electric motor

TCVN 7450-1:2013

Applicable to 3-phase squirrel cage rotor asynchronous electric motors with capacity from 0.75kW to 150kW, nominal voltage up to 1000V; has 2,4 or 6 poles; operates in S1 mode;

Exclude the following cases:

□ Has a built-in gearbox that cannot be removed without damaging the engine;

□ Fully integrated engine

□ Engine operating in an explosive gas field

□ Engine designed specifically for the environment and special characteristics

 

- - - Capacity not exceeding 1 kW:

8501.52.19

- - - - Others

 

- - - Capacity over 1 kW but not exceeding 37.5 kW:

8501.52.29

- - - - Others

 

- - - Capacity above 37.5 kW but not exceeding 75 kW:

8501.52.39

- - - - Others

8501.53.90

- - Others

8402.11.20

- - - Not electrically operated

Industrial boiler

TCVN 8630:2010

TCVN 8630:2019

 

8402.12.21

- - - - Boilers with steam capacity over 15 tons/hour

8402.12.29

- - - - Others

8402.19.21

- - - - Boilers with steam capacity over 15 tons/hour

8402.19.29

- - - - Others

8402.20.20

- - Not electrically operated

8504.21

- - With a capacity not exceeding 650kVA

Transformers

TCVN 8525:2015

3-phase distribution transformers with nominal capacity from 25 kVA to 2,500 kVA including dry transformers

8504.21.19

- - - - Others

8504.21.92

- - - - Having a nominal capacity of over 10 kVA and a high voltage output of 110kV or more

8504.21.93

- - - - Having a nominal capacity of over 10 kVA and a high voltage output of 66 kV or more, but less than 110 kV

8504.21.99

- - - - Others

8504.22

- - Capacity over 650kVA but not exceeding 10,000kVA

 

- - - Stepped voltage stabilizer (autotransformer):

8504.22.11

- - - - High voltage terminals of 66 kV or more

8504.22.19

- - - - Others

 

- - - Others:

8504.22.92

- - - - High voltage terminals from 110kV or more

8504.22.93

- - - - High voltage terminal from 66kV or more, but less than 110kV

8504.22.99

- - - - Others

More details can be found in Decision 1725/QD-BCT effective in Vietnam from July 01, 2024.

>> CLICK HERE TO READ THIS ARTICLE IN VIETNAMESE

0 lượt xem



  • Address: 19 Nguyen Gia Thieu, Vo Thi Sau Ward, District 3, Ho Chi Minh City
    Phone: (028) 7302 2286
    E-mail: info@lawnet.vn
Parent company: THU VIEN PHAP LUAT Ltd.
Editorial Director: Mr. Bui Tuong Vu - Tel. 028 3935 2079
P.702A , Centre Point, 106 Nguyen Van Troi, Ward 8, Phu Nhuan District, HCM City;