Hanoi-Vietnam: Minimum performance of water heaters

On December 28, 2017, the Vietnam Ministry of Construction issued Circular 15/2017/TT-BXD specifying the minimum performance of water heaters.

The minimum performance of water heaters in Vietbnam regulated by Circular 15 is as follows:

Type of Equipment

Minimum performance ET, %

Gas-fired hot water storage heaters

78

Gas-fired instantaneous water heaters

78

Gas-fired hot water supply boilers

77

Oil-fired hot water supply boilers

80

Gas and oil-fired hot water supply boilers

80

Boilers with a thermal power capacity of 10-350 kW, burning wood and paper

60

Boilers with a thermal power capacity of 10-2000 kW, burning brown coal

70

Boilers with a thermal power capacity of 10-2000 kW, burning stone coal

73

Electric-resistance water heating units

Emin = 5.9 + 5.3V0.5 (W)

NOTES:

- The minimum performance of gas or oil-fired water heating units is given as thermal efficiency, which includes heat loss from the unit's compartments;

- The minimum performance of electric-resistance water heating units is determined from the maximum standby loss (SL) when the temperature difference between the heated water and the surrounding environment is 40°C. In the above formula, V is the volume measured in liters;

- Testing procedure to be conducted according to ANSI Z21.10.3 standards or other applicable standards for the project.

Details may be found in Circular 15/2017/TT-BXD effective from June 1, 2018.

-Thao Uyen-

>> CLICK HERE TO READ THIS ARTICLE IN VIETNAMESE

0 lượt xem



  • Address: 19 Nguyen Gia Thieu, Vo Thi Sau Ward, District 3, Ho Chi Minh City
    Phone: (028) 7302 2286
    E-mail: [email protected]
Parent company: THU VIEN PHAP LUAT Ltd.
Editorial Director: Mr. Bui Tuong Vu - Tel. 028 3935 2079
P.702A , Centre Point, 106 Nguyen Van Troi, Ward 8, Phu Nhuan District, HCM City;